The method string used in rave::VertexFactory
has the following general structure:
finder-name:value-name:value-...
Sometimes nesting is required (e.g. to configure "sub-algorithms"):
finder-name:value-name:(value-name:value-name:value)....
As for the finders, the following algorithms are defined:
- kalman KalmanVertexFitter This is the simple linear kalman filter that takes no extra parameters.
- avf
AdaptiveVertexFitter The avf respects the following parameters:
- sigmacut: The value for [ = sqrt (2) ] at which a track has track weight=0.5.
- Tini: Initial temperature in the annealing schedule.
- ratio: The ratio with which the temperature falls in each iteration step.
Default is: avf-Tini:256-ratio:0.25-sigmacut:3
- tkf
TrimmedKalmanVertexFinder? The tkf respects the following parameters:
- ptcut: Cut in the tracks' pT, given in GeV/c.
- vtxcut: Bla FIXME
- trackcutpv: Bla FIXME
- trackcutsv: Bla FIXME
Default is: tkf-ptcut:0-trkcutpv:0.05-trkcutsv:0.01-vtxcut:0.01
- mvf
MultiVertexFitter?:
- sigmacut
Default: mvf-sigmacut:9.0
- avr
AdaptiveVertexReconstructor: Iterative adaptive vertex fitting.
- primcut: Cut (in terms of sigma) on the primary (i.e. first) vertex
- seccut: Cut (in terms of sigma) on all subsequent vertices)
- minweight: Minimum track weight to be used in subsequent avf fits.
Default is: avr-minweight:0.5-primcut:2-seccut:6
Last modified 18 years ago
Last modified on Jun 9, 2007, 10:33:31 PM